HARVIA HIMALAYA FULL-SPECTRUM INFRARED SAUNA — 3 PERSON
Model: Himalaya IR 3 Person
Model Number: HAR-8003-01
Sauna Type: Full-spectrum infrared sauna
Capacity: Up to 3 people
Application: Indoor residential use
Operating Format: Dry infrared heat; no heater stones, water, or steam
Country of Origin: China
• Clear-hemlock modular cabin
• Full-width bench
• Bronze privacy tempered-glass front
• Eight infrared heating elements
• Integrated infrared floor heater
• Digital temperature and timer controls
• Temperature sensor
• Himalayan salt-bar lighting
• Chromotherapy lighting
• Bluetooth audio system
• Built-in speakers
• MP3 auxiliary connection
• Adjustable roof vent
• Integrated floor panel
• Roof panel and roof cover
• Power-supply system
• Assembly hardware
Exterior Dimensions: 61⅛″ W × 40 9⁄16″ D × 74 13⁄16″ H
Interior Dimensions: 57⅝″ W × 40″ D × 69″ H
Assembled Weight: Approximately 405 lb
Exterior Material: Clear Canadian hemlock
Front Glass: Bronze privacy tempered glass
Vent Location: Adjustable roof vent
Installation Format: Freestanding modular cabin
Seating Capacity: Up to 3 adults
Bench Configuration: Single-level, full-width hemlock bench
Heat Placement: Infrared emitters positioned along the side walls, rear wall, and floor
Lower-Body Heating: Integrated floor heating panel
Interior Atmosphere: Illuminated Himalayan salt bars and color-changing light therapy
Controls: Digital controls accessible from inside the cabin
Floor: Integrated wood floor panel
The surrounding heater placement delivers radiant warmth across the back, sides, legs, and feet while allowing the cabin to operate at a lower air temperature than a traditional sauna.
Cabin Material: Clear Canadian hemlock
Bench Material: Hemlock
Glass: Bronze privacy tempered safety glass
Wall Construction: Prefabricated wood wall panels
Panel Connections: Metal buckles, guide brackets, and guide inserts
Floor Construction: Integrated floor panel with infrared heater
Roof Construction: Removable roof panel and protective roof cover
Interior Hardware: Himalayan salt-panel support, temperature sensor, controls, lighting, and audio components
Electrical Supply: 120 VAC
Circuit Requirement: Dedicated 20-amp circuit
Total Heating Output: 2,200 W
Connection Type: Plug-in connection
Outlet Location: Must remain accessible after installation
Shared Circuit: Not permitted while the sauna is operating
Extension Cords: Not permitted
Surge Protectors or Receptacle Adapters: Not permitted
The manufacturer’s manual does not recommend a GFCI-protected receptacle or breaker for this model. Final electrical preparation, including any locally required GFCI or AFCI protection, must be confirmed by a licensed electrician and comply with applicable electrical codes.
Heating Format: Full-spectrum near- and far-infrared heat
Total Heating Elements: Eight
Total Output: 2,200 W
Heat Distribution: Full-body surround heating
Heating Configuration:
• Two 300 W side-wall carbon heating panels
• Two 200 W side-wall carbon heating panels
• Three 300 W near-infrared emitters
• One 300 W infrared floor heating panel
The carbon panels deliver broad far-infrared warmth, while the near-infrared emitters provide more concentrated radiant heat. The integrated floor panel extends warmth to the legs and feet.
Operating Temperature: Up to approximately 120°F
Heat Delivery: Direct radiant heat rather than high-temperature air heating
Warm-Up Performance: Fast heat-up with infrared energy directed toward the body
Temperature Adjustment: One-degree increments
Session Timer: Adjustable from 5 to 60 minutes
Temperature Display: Selectable Fahrenheit or Celsius
Heat Regulation: Integrated temperature sensor cycles the heating system as the selected temperature is reached
Humidity: Low-humidity, dry infrared environment
Continuous-Use Limitation: After three continuous hours of operation, the sauna must remain off for at least one hour
System Classification: Near-zero-EMF full-spectrum infrared system
Full-Spectrum System Measurement: Less than 3 mG at approximately two inches from the heating panels
Near-Infrared Emitter Measurement: Approximately 5–7 mG at approximately two inches
The near-infrared emitters have a different measured EMF range from the broader carbon heating panels. Both measurements should be disclosed rather than describing the entire system with a single generalized EMF figure.
Control System: Digital LED microprocessor controls
Control Access: Interior and exterior control access
Temperature Management: Adjustable digital temperature settings
Automatic Heat Regulation: Heating indicator and temperature sensor regulate output around the selected temperature
Timer Intelligence: Programmable 5-to-60-minute session timer
Temperature Format: Fahrenheit and Celsius display options
System Monitoring: Integrated temperature sensor
Diagnostic Display: Error indicators identify temperature-sensor faults and excessive cabin temperature
Remote Control: Not included
Wi-Fi Connectivity: Not included
Mobile-App Control: Not included
Audio System: Built-in speakers
Wireless Audio: Bluetooth connectivity
Wired Audio: MP3 auxiliary input
Mobile Application: No dedicated sauna-control application
Streaming Integration: Audio streams through a connected Bluetooth-enabled device
Interior Lighting: Integrated color-changing light
Chromotherapy: Multiple selectable color-light settings
Salt Feature: Illuminated Himalayan salt bars
Light Controls: Integrated into the digital control system
Ventilation Type: Passive, manually adjustable ventilation
Vent Location: Roof
Operation: The ceiling vent may be used in the open or closed position during operation
Active or Motorized Ventilation: Not included
This model uses an adjustable passive roof vent rather than a fan-powered active ventilation system.
Assembly Format: Prefabricated modular panel system
Recommended Installers: Two adults
Required Tools: Phillips screwdriver and ladder
Panel Connection: Buckle, guide, and guide-insert assembly
Installation Surface: Solid, dry, and level finished floor
Installation Environment: Dry indoor location away from direct water exposure
Electrical Access: Dedicated outlet must remain accessible
Water Clearance: Do not install where the cabin may be exposed to water from a bathtub, shower, pool, or wet-room environment
Professional Electrical Work: Required if a compliant dedicated 120 V, 20-amp outlet is not already available
The sauna is assembled in sections that include the floor, front wall, side walls, rear wall, salt-panel support, floor heater, bench, roof panel, and roof cover.
Heating Elements and Electronics: Five-year limited warranty
Radio and Audio Components: One-year limited warranty
Wood Structure: One-year limited warranty
Coverage: Defects in materials and workmanship
Labor: Not included
Transferability: Non-transferable
Eligible Owner: Original purchaser only
Eligible Location: Original installation site
Geographic Coverage: Continental United States and Canada
Outdoor installation, relocation, unauthorized modification, improper installation, commercial use, exposure to weather, and failure to follow the manufacturer’s instructions may void warranty coverage.
Certifications: The current product page and owner’s manual do not identify a specific third-party electrical or safety certification for the HAR-8003-01. Certification and jurisdictional approval should be confirmed with the manufacturer or authorized dealer before ordering.
Routine Cleaning: Wipe the interior with clean water and a soft, damp cloth
Cleaning Products: Do not use liquid cleaners, aerosol cleaners, alcohol, benzene, or strong chemical products
Electrical Safety: Unplug the sauna before cleaning
Moisture Protection: Keep the cabin dry and away from direct water exposure
Storage: Do not store the sauna or its components in a damp environment
Weather Exposure: Protect from rain, snow, direct outdoor exposure, and extreme weather
Pre-Use Inspection: Inspect the cabin and heating system for proper operation before each session
Post-Delivery Inspection: Inspect all infrared heating elements for transportation damage before assembly or operation
Extended Inactivity: Unplug the sauna when it will not be used for an extended period
Repairs: Use manufacturer-approved replacement components and authorized service providers
Specifications, included components, warranty terms, and electrical requirements may be updated by the manufacturer. Final site preparation must be based on the current manual and the identification label supplied with the ordered unit.